  1. ***************************************************************************
  2. *                                                                         *
  3. *  PROTEC NET Version 4.1                                                 *
  4. *                                                                         *
  5. *  Copyright (C) IPE Corporation, Ltd.                                    *
  6. *  9 Alfred Place                                                         *
  7. *  London, WC1E 7EB                                                       *
  8. *                                                                         *
  9. *  Telephone: +44 (0)71 436 2244       Fax: +44 (0)71 916 1004            *
  10. *                                                                         *
  11. *                                                                         *
  12. ***************************************************************************
  13.  
  14. Dear Netware Manager,
  15.  
  16. Many thanks for your interest in Protec Net for Novell. The fact that 
  17. you have this product in your hands indicates that you have some interest in 
  18. extending your control from the server to other parts of your network.
  19.  
  20. Protec Net is designed just for that. The product provides a host of benefits 
  21. which will become apparent as you work through them.
  22.  
  23. And, if what you see is not enough, there is a whole lot more in store in new
  24. versions during the coming months.
  25.  
  26. If you purchase this product, you will automatically receive all the version
  27. updates for 12 months after your purchase.
  28.  
  29. This Evaluation Pack is only suitable for installation on 1 Novell Server and 
  30. is restricted to install on 2 workstations. Once you have installed the 
  31. product and set up the system to suit your environment, you need not remove 
  32. it or change it in anyway if you wish to purchase the product. Simply place
  33. your order with your local dealer, and we will upgrade this evaluation pack
  34. over the phone.
  35.  
  36. Yes, that is all it takes. A quick phone call can increase this licence to 
  37. a 5, 10, 25, 50 or 100 user licence.
  38.  
  39. Please read the attached notes before you proceed with installation of this
  40. software.
  41.  
  42. Good Luck, and I hope that we can be of continuous service to you and your 
  43. company.
  44.  
  45.  
  46. Yours sincerely,
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54. Garth McLeod
  55. Managing Director
  56.  
  57.  
  58. -------------------------------------------------------------------------------
  59. Protec NET 4.1, 21st November 1994
  60.  
  61. Technical Bulletin No. 008
  62. --------------------------
  63.  
  64. 1.    Problems may be experienced in certain configurations with Netware 4.0
  65.       and we would have to advise that at this stage we can only guarantee 
  66.       compatibility with Novell Netware versions 3.11 and 3.12.
  67.  
  68. 2.    In evaluation, you may like to re-initialise the databases without 
  69.       re-installing, and this can be achieved with the following command 
  70.       (you will of course be logged in as supervisor); 
  71.  
  72.             PINIT /R /OPEN
  73.  
  74.       However, this command does not clear out any user shells or Protec NET 
  75.       script commands from the respective logon scripts. To do this you must 
  76.       actually remove Protec NET with the command RMPROTEC.
  77.  
  78. 3.    Denying access to COM and LPT ports works fine so long as the program 
  79.       in question uses DOS. However, some programs talk to these ports 
  80.       directly (ie. using OUTP) and though we do deny access to the port, 
  81.       other applications may not be able to handle the denial, and will simply
  82.       sit there waiting. In technical parlance, this is known as 'hanging'.
  83.  
  84. 4.    Using certain programs that access the disk in an unorthodox way 
  85.       (ie. Windows File Manager, Xtree Gold, etc.) you may think permissions
  86.       are not working because you might be able to view restricted files and 
  87.       directories. However, you cannot actually access them, so permissions 
  88.       are not in fact compromised.
  89.  
  90. 5.    We make some initial checks to ensure that CHKDSK will not run, but it 
  91.       should be understood that keeping users from dangerous commands is the 
  92.       System Manager's responsibility. In particular, we recommend that users 
  93.       be locked from the following commands;
  94.  
  95.             CHKDSK, SCANDISK (DOS 6.x), Norton Utilities, PC-Tools, DEBUG, 
  96.             and so on....
  97.  
  98.       Disallowing low-level IO can help minimise possible damage, but we cannot
  99.       guarantee it will prevent ALL malicious attempts.
  100.  
  101. 6.    With low-level IO disallowed, Windows 32-bit access will also be
  102.       disabled.
  103.  
  104. 7.    After installing the number of allowed workstations (2 in the case of
  105.       an evaluation) you may wish to remove one, and install on another 
  106.       workstation. In order to achieve this, you should perform the following
  107.       steps;
  108.  
  109.       a.    Run PSECURE in the \system\protec directory
  110.       b.    Under the Workstation menu, select 'Add/Remove workstation'
  111.       c.    Go to the appropriate record and press <DEL>
  112.       d.    Under the File menu, select the option 'Optimise data files'
  113.  
  114.       After this, you will be able to install on a different workstation.
  115.  
  116. 8.    Drive level encryption is not fully implemented in this release. File
  117.       and directory encryption works fine, so the same result can be 
  118.       achieved.
  119.  
  120. 9.    While using the file selection utility for encryption, permissions and
  121.       program selection, if you try to access files in the root directory of
  122.       the first network volume you may experience frequent share violations.
  123.       They will clear, but are due to accessing BACKOUT.TTS, a file in almost
  124.       continuous use by Netware. This will be filtered out in the next 
  125.       release...
  126.  
  127. 10.   Using VLMs one must have LASTDRIVE set also.
  128.  
  129. 11.   If you put the AUDIT switches on, then it is a good idea to increase
  130.       the size of the AUDIT MEMORY BUFFER.
  131.  
  132. 12.   There are occasions when we will not install on to a workstation due to 
  133.       some or other problem with AUTOEXEC. It is wise therefore, to ensure that
  134.       recipient workstations are in a reasonable state, and that there are no 
  135.       commands in the AUTOEXEC that will prevent the running of LOADER (which 
  136.       we place at the end of the file.) Also, ensure that the recipient 
  137.       workstations have calls to the network drivers located in this file. 
  138.  
  139.       Valid network drivers are contained within the NETWORK DRIVERS section
  140.       of the Protec NET setup file PSETUP.INF.
  141.  
  142.       Reasons as to why a workstation could not be installed are contained in 
  143.       the comments field at the end of the workstation record, under the 
  144.       Install/Update/Remove protec option of PSECURE.
  145.  
  146. 13.   Due to problems between Netware 3.xx login and DOS environments, it has
  147.       been necessary to provide our own login/logout/map programs. These are 
  148.       intended to work identically to Netware programs, except that they fix
  149.       the environment problem, and they are Protec aware. However, under 
  150.       certain conditions, they may not appear to work exactly the same, but
  151.       this should not affect any login/logout/map functions.
  152.  
  153.       And remember, the original programs are copied to the \login\old 
  154.       directory, and renamed with a NV prefix (nvlogin, nvlogout, nvmap)
  155.       so if in doubt, you may always use these.
  156.  
  157.       In the next release of Protec Net (with Netware 4.xx compatibility) a 
  158.       new method has been employed that will clear the environment problems
  159.       without replacing Netware programs.
  160.  
  161.  
  162.  
  163. -------------------------------------------------------------------------------
  164. If you have even the smallest problem or query then please contact Sa'eed or
  165. Adrian of IPE Technical Support, +44 (0)71 436 2244, who will be only too
  166. pleased to resolve it.
  167.  
  168.